350KW Marine Generator
350KW Marine Generator
Prime 350KW Cummins Marine Generator Set with 50Hz Power Rating, marine CCS/IMO approved, available for 60HZ Power Rating. Optional for Stamford or Marathon Alternator, standard Cummins marine Controller. High Standard and New Genuine Quality Cummins Marine Generators! Agent Wholesale: Cummins KTA19-D(M) engine, Alternator & spares!

Worldwide Services

Genuine Quality

30 Days Delivery

Worldwide Shipping

Verified Certificates

15 Working Days
350KW Marine Generator

Voltage/Frquency
440V/60Hz

Winding, Factor
3P, 0.8 PF

Rated Power/Rated Speed: 350 kW/437.5 kva
Standby Power/Rated Speed: 385 kW/482 kva

Engine Type
Cummins KTA19-D(M)

Alternator
Stamford HCM534C or Marathon MX-H-350-4

Control System
Random
Weight and Dimension
Open type
1666 mm x 874 mm x 1377 mm
2005 kg
Silent Type
1999 mm x 1136 mm x 1721 mm
2406 kg
Engine Specification
Engine Model | Cummins KTA19-D(M) | |||||||
Engine Type | 6 Cylinders, in Line | |||||||
Bore * Stroke (mm * mm) | 159*159 | |||||||
Displacement | 19 L | |||||||
Rated Power/Speed | 392kw (525HP)/ 1800rpm | |||||||
Standby Power/Speed | 369kw (495HP)/ 1800rpm | |||||||
Aspiration/Cooling System | Turbocharged, Aftercooled/Water-cooled | |||||||
Governor Method | Mechanical Governor |
Alternator Specification
Alternator Model | Stamford HCM534C | ||||
Voltage/Frequency | 230/400V, 50 HZ | ||||
Winding/Power Factor | 3-phrase, 4-wire, 0.8 | ||||
Exciting Method | Brushless Self-exciting | ||||
Insulation/Protection Class | Class H, IP23 | ||||
Winding Pitch/Regulator | Two Thirds, AVR |
350KW Marine Generator

Voltage
440V/60Hz

Winding, Factor
3P4W, 0.8 PF

Rated Power/Rated Speed: 350 kW/437.5 kva
Standby Power/Rated Speed: 385 kW/482 kva

Engine Type
Cummins KTA19-D(M)

Alternator
Stamford HCM534C or Marathon MX-H-350-4

Control System
Random
Weight and Dimension
Open type
1666 mm x 874 mm x 1377 mm
2005 kg
Silent Type
1999 mm x 1136 mm x 1721 mm
2406 kg
Engine Specification
Engine Model | Cummins KTA19-D(M) | |||||||
Engine Type | 6 Cylinders, in Line | |||||||
Bore * Stroke (mm * mm) | 159*159 | |||||||
Displacement | 19 L | |||||||
Prime Power | 392kw (525HP)/ 1800rpm | |||||||
Standby Power | 369kw (495HP)/ 1800rpm | |||||||
Aspiration/Cooling System | Turbocharged, Aftercooled/Water-cooled | |||||||
Governor Method | Mechanical Governor |
Alternator Specification
Alternator Model | Stamford HCM534C | ||||
Voltage/Frequency | 230/400V, 50 HZ | ||||
Winding/Power Factor | 3-phrase, 4-wire, 0.8 | ||||
Exciting Method | Brushless Self-exciting | ||||
Insulation/Protection Class | Class H, IP23 | ||||
Winding Pitch/Regulator | Two Thirds, AVR |
Assembly/Warranty

350KW Marine Generator coupled with full torsion analysis, Anti-vibration pads, have been treated by grit blast cleaning and coating. Then covered by special three layers painting. Generator, engine, alternator, control system are marine standard with CCS inspection.

All generating sets have gone through rigorous testing before delivery, including 50% load, 75% load, 100% load, 110% load and all protection function, (over-speed stop, high water temp., low oil pressure, battery charging failure, emergency stop)

350KW Marine Generator Criterion: Standard Marine CCS & IMO certificates. ISO8528, GB/T2820, ISO3046, BS4999, BS5514, BS5000, EN12601:2001, EN60034- 22:1997, EN60204-1:2006, ISO9001:2000 Quality Management & ISO14001:2004, SGS, TLC.

ASAHI provides one-source responsibility and 350KW Marine Generator spares, with 12 months or 1000 hours global warranty.
Assembly/Warranty

350KW Marine Generator coupled with full torsion analysis, Anti-vibration pads, have been treated by grit blast cleaning and coating. Then covered by special three layers painting. Generator, engine, alternator, control system are marine standard with CCS inspection.

All generating sets have gone through rigorous testing before delivery, including 50% load, 75% load, 100% load, 110% load and all protection function, (over-speed stop, high water temp., low oil pressure, battery charging failure, emergency stop)

350KW Marine Generator Criterion: Standard Marine CCS & IMO certificates. ISO8528, GB/T2820, ISO3046, BS4999, BS5514, BS5000, EN12601:2001, EN60034- 22:1997, EN60204-1:2006, ISO9001:2000 Quality Management & ISO14001:2004, SGS, TLC.

ASAHI provides one-source responsibility and 350KW Marine Generator spares, with 12 months or 1000 hours global warranty.